Information HubService
Cleaning, repair and refurbishment
Flow cells can often be reworked instead of replaced. We evaluate each part and tell you what is possible, or manufacture an identical replacement.
- CleaningReworking and cleaning of flow cells.
- RepolishingRepolishing, if necessary.
- RepairWe evaluate whether repair is possible.
- ReplacementAn identical replacement part, if repair is not.
How it works
- Tell us about the partSend the part number or drawing and describe the damage or contamination.
- We evaluateWe check whether cleaning, repolishing or repair is possible.
- Rework or replaceWe rework the part, or manufacture an identical replacement.
Replacement parts for existing instruments
Many OEM designs can be replicated 1:1 with our manufacturing methods. If you wish, we can also offer retrofit solutions.
Maintenance for process probes and flow cells
A planned service instead of an unplanned shutdown.
An immersion probe or flow cell that fails during production costs far more than the part. Regular maintenance lowers that risk. A maintenance package is a precaution that saves time and money:
- More reliable processes and better plant efficiency
- Fewer unplanned shutdowns and the costs that come with them
- Support for meeting standards and legal requirements
- A longer service life for the probe
- A warranty on all work carried out
- ConsultationWe talk through your probe, your process and what you need.
- Check process conditionsTemperature, pressure and medium decide which seals and checks are needed.
- SchedulingWe agree a date so the probe is out of service as briefly as possible.
- Send in the productYou send the probe or flow cell to Hellma.
- MaintenanceInspection, new seals, cleaning, testing and documentation.
- ReturnThe probe comes back with its test certificate and maintenance protocol.
What the maintenance package includes (processing time about 7 days, plus shipping):
- Incoming inspection, documented
- Complete immersion probe dismantled and examined
- Elastomer seals of the optical parts replaced (except Falcata path-length tips)
- Cleaning and reassembly
- Helium leak test, with certificate
- Pressure test
- Test measurement with spectrum
- Maintenance protocol
- 1-year warranty on all work performed and wear parts replaced
Recalibration of UV/Vis calibration standards
Accredited recalibration, so your spectrophotometer checks stay traceable.
Laboratory balances get calibrated as a matter of course; spectrophotometers are often forgotten. Under DIN EN ISO 9001 they are measuring instruments that must be calibrated too, using standards traceable to national or international measurement standards.
Hellma's calibration laboratory is accredited by DAkkS to DIN EN ISO/IEC 17025 (certificate D-K-18752-01-00, for the scope in its annex). It tests and recalibrates Hellma calibration standards, and standards from other manufacturers: glass filters, liquid filters and 96-well reference plates. Filters are usually recalibrated within five working days of arriving at the laboratory and come back with a calibration certificate.
- Send the filtersWith the details listed below.
- Material and parametersWe verify the filter material and set the recalibration parameters.
- Integrity checkEach filter is checked for damage such as scratches.
- RecalibrationMeasured in the accredited laboratory.
- Certificate and returnFilters come back with their calibration certificate.
What to send with your filters: article number, serial number, the wavelengths and slit widths to be measured, whether you want a measurement documented before cleaning, your quotation number if you have one (and your order number on the delivery note), billing and delivery addresses, and any special requests such as extra wavelengths.
Shipping liquid filters in winter: liquid filters can freeze and be destroyed below 4 °C (39 °F). From November to March, ship them by express only.
Everyday care
Most cuvette problems start with cleaning. Hellma recommends its alkaline cleaning concentrate Hellmanex® III for glass and quartz glass cuvettes and other optical parts: it lifts dirt, keeps it from settling back, and rinses off without leaving UV/Vis-active residue.
- Soak cuvettes in Hellmanex III diluted to 2 % with water. For flow-through cuvettes, pump the solution through the cell.
- Warming the bath gently and agitating it speeds up cleaning.
- Rinse thoroughly with ultrapure water, changing the rinse water at least three times.
- Blow dry with clean air and let the cuvettes dry where there is no dust, or rinse with a volatile solvent such as ethanol and let it evaporate.
Avoid ultrasonic baths and sudden temperature changes, never handle cuvettes with metal tweezers, and don't let cleaning solution dry inside a hot cuvette. Clean, dry and store cuvettes in their cases straight after measuring.
- Hellmanex® III and accessoriesCleaning concentrate, holders, caps and stoppers.Shop
- Quality and traceabilityCertificates and documentation for replacement parts.Read more
Questions
Can you clean or refurbish flow cells?
Yes. We offer reworking, cleaning and, if necessary, repolishing.
Can you help if a flow cell is damaged?
We evaluate whether repair is possible, or manufacture an identical replacement part.
Can we obtain replacement flow cells for existing instruments?
Yes. Many OEM designs can be replicated 1:1 with our manufacturing methods. If desired, we can also offer retrofit solutions.
How often should UV/Vis calibration standards be recalibrated?
The interval is up to you and depends on your laboratory environment. Hellma recommends recalibrating every 12 months for the first three years, then setting the interval from the data those three years provide. Review the interval as part of your formal system control, and whenever the laboratory environment changes significantly.
How long does recalibration take?
Filters are usually recalibrated within five working days of arriving at the Hellma calibration laboratory, plus shipping both ways.
Can you recalibrate calibration standards from other manufacturers?
Yes. The DAkkS-accredited Hellma laboratory recalibrates standards from other manufacturers as well as Hellma's own, within the scope of its accreditation.
What does probe maintenance include, and how long does it take?
Incoming inspection, complete dismantling and examination, new elastomer seals on the optical parts, cleaning, reassembly, a helium leak test with certificate, a pressure test, a test measurement with spectrum and a maintenance protocol. Processing takes about 7 days plus shipping, and all work and replaced wear parts carry a 1-year warranty.
Have a damaged or worn part?
Send us the part number or drawing and a short description. We will tell you whether rework is possible.